Double-stud partition
Two independent metal stud frames + 100 mm Rockton stone wool in each cavity + 2 × 12.5 mm plasterboard on each side. Rw+C = 54 to 58 dB. The best performance without masonry.
Acoustic partitions, suspended ceilings, anti-vibration floors — Rockwool, Knauf, ISOVER. Rw+C ≥ 50 dB. QUASART treats noise in Luxembourg, Moselle, Meurthe-et-Moselle and the Belgian province of Luxembourg.
Dense stone wool is an exceptional acoustic insulation material. By integrating acoustic insulation into the same project as thermal insulation, QUASART achieves significant savings — shared installation, shared finishes.
Double-stud metal partitions with Rockwool Rockton stone wool achieve Rw+C ≥ 50 dB — the upper limit of Luxembourg regulatory requirements. QUASART, based in Crauthem (L-3327), designs each project to NF EN 12354 standards and Luxembourg regulations.
Density and thickness are the two key factors in acoustic performance.
High-density stone wool — the absolute benchmark for the acoustic insulation of partitions. Density 40-60 kg/m³, non-combustible A1. Excellent absorption of mid and low frequencies (voices, music, TV).
BenchmarkSemi-rigid glass wool — a good acoustic/thermal/price compromise. Less effective than stone wool at equal density, but more economical. Formaldehyde-free treatment (ECOSE).
VersatileResilient polyurethane foam or bitumen felt underlay beneath a floating screed. Reduces impact sound (knocks, footsteps, falling objects). Delta Lw ≥ 25 dB. Mandatory in new apartment buildings.
Impact soundElastomer anti-vibration hangers for suspended ceilings. They decouple the ceiling from the structure and intercept the vibrations transmitted by the floor above. Essential in apartment renovation.
CeilingThe finish influences acoustic performance — every board plays a role.
QUASART works with European acoustic insulation specialists.
World leader in stone wool. Rockton (partitions, density 50 kg/m³), Rockmur (wall linings), Rockfon (ceiling tiles, absorption α > 0.90). The benchmark choice for apartment buildings, offices and public buildings.
Complete acoustic systems — Knauf Insulation TP (acoustic glass wool), Diamant boards (high density, +3 dB), AMF Thermatex tiles (ceilings). Knauf metal profiles optimised for acoustic performance.
ISOVER acoustic range. Calibel (bonded acoustic composite), PAR Phonic (acoustic glass wool), Optima Sonic (integrated wall system). Solutions tested in the CSTB laboratory — certified performance.
Acoustic plasterboards. Placo Phonique (−3 dB vs standard 12.5 mm plasterboard), Duo Tech (pre-bonded acoustic double board), Rigidur (high-strength gypsum fibre). The ideal complement to stone wool to maximise Rw.
Two independent metal stud frames + 100 mm Rockton stone wool in each cavity + 2 × 12.5 mm plasterboard on each side. Rw+C = 54 to 58 dB. The best performance without masonry.
Single stud frame + 90 mm stone wool + 2 × 12.5 mm plasterboard + perimeter sealant treatment. Rw+C = 48-52 dB. Intermediate solution for standard apartment buildings.
Ceiling on anti-vibration spring hangers + stone wool + plasterboard or mineral tiles. Reduces impact and airborne sound from the floor above. Very effective in renovation.
Resilient underlay (PU foam, bitumen felt) beneath a floating screed — reduces impact sound. Delta Lw ≥ 25 dB. Mandatory in new apartment buildings in Luxembourg.
Perimeter resilient strips, decoupled boxes for sockets and switches, sealing of service penetrations. Details make the difference between Rw 48 and Rw 54.
Dense stone wool (λ 0.035) combines thermal and acoustic performance. One project, two results — a low marginal cost to move from a thermal lining to an acoustic partition.
Acoustic performance depends as much on installation as on materials — every detail counts.
Measurement of the existing noise (sound level meter), identification of the sources (airborne, impact, equipment). Predictive calculation to NF EN 12354. Specification tailored to the regulatory or comfort target.
Sound level meter · EN 12354 · SourcesTracks fixed with a perimeter resilient strip (floor, ceiling, side walls). Independent studs for the double-stud frame. No rigid contact between the two leaves — decoupling is the key.
Resilient · Independent · DecoupledRockton stone wool friction-fitted between the studs — full fill, no voids. Every unfilled space is an acoustic bridge. Thickness 45 to 100 mm per cavity depending on the target performance.
Full fill · Rockton · 0 voids2 × 12.5 mm plasterboard screwed on each side, joints staggered. Joint tape, filler, paint. Decoupled boxes for sockets. No through-penetrations — each screw must stay within its own leaf.
2 × plasterboard · Staggered · Decoupled boxesAcoustics in Luxembourg is governed by precise regulatory requirements.
European standard for predicting sound insulation — airborne sound (part 1), impact sound (part 2), outdoor noise (part 3). The design basis used by QUASART.
Standard for determining the weighted sound reduction index Rw in the laboratory and on site. Adaptation terms C (pink noise) and Ctr (road traffic noise).
Standard for determining the weighted impact sound pressure level Ln,w. The basis for the Delta Lw of acoustic underlays beneath floating screeds.
Reference DTU for plasterboard partitions and linings — framing, fixings, joints, acoustic detailing.
Certification of the acoustic and thermal performance of insulation products — absorption index, dynamic stiffness, certified lambda.
DnT,A ≥ 53 dB between adjoining dwellings, DnT,A ≥ 58 dB for separating walls with common areas. Measured on site — QUASART designs with a 3-5 dB margin.
Double-stud separating partition Rw+C ≥ 53 dB between dwellings. Luxembourg regulations are demanding — QUASART designs with a 3-5 dB margin to target compliance on site.
Acoustic partitions between offices, meeting rooms and open-plan areas. Sound-absorbing acoustic ceilings (Rockfon, AMF). Working comfort and productivity.
Buildings open to the public have stricter acoustic requirements. Reverberation time, sound insulation between rooms, equipment noise — QUASART masters the specific constraints of public buildings.
Footsteps from the neighbour above? A suspended ceiling on anti-vibration spring hangers + stone wool. Or a resilient underlay beneath a floating screed if it is your floor that transmits the noise.
Acoustics is the invisible side of comfort. You only notice silence when you have lost it — and you never forget it when you have found it again.QUASART — Installation philosophy
Everything you need to know
Luxembourg regulations require DnT,A ≥ 53 dB between adjoining dwellings and DnT,A ≥ 58 dB for separating walls with common areas. These values are measured on site — QUASART designs with a 3-5 dB margin to target compliance.
No — a simple 12.5 mm plasterboard partition (without insulation) achieves about Rw 38 dB. Conversation remains audible. For acceptable comfort, Rw ≥ 50 dB is needed, which requires a reinforced single-stud or a double-stud frame with stone wool.
Airborne sound travels through the air (voices, music, TV) — it is reduced with mass and insulation (partitions, linings). Impact sound travels through the structure (footsteps, falling objects) — it is reduced by decoupling (spring hangers, resilient underlay, floating screed).
Partly — a suspended ceiling on spring hangers (without touching the walls) provides Delta Rw 15-20 dB. Sound-absorbing acoustic tiles reduce reverberation. But to meet the regulatory requirements between dwellings, a structural intervention (double-stud partition) is generally needed.
Yes, at equal density. Stone wool (40-60 kg/m³) absorbs low and mid frequencies better than glass wool (15-25 kg/m³). For demanding separating partitions (Rw ≥ 53 dB), QUASART systematically recommends Rockwool Rockton stone wool.
The cost depends on the chosen configuration. A double-stud partition with Rockton stone wool (Rw+C ≥ 54 dB) costs more than a standard plasterboard partition, but the acoustic comfort achieved is incomparable. Contact QUASART for a free quote.