Acoustic insulation

Acoustic
Insulation

Acoustic partitions, suspended ceilings, anti-vibration floors — Rockwool, Knauf, ISOVER. Rw+C ≥ 50 dB. QUASART treats noise in Luxembourg, Moselle, Meurthe-et-Moselle and the Belgian province of Luxembourg.

Rw+C ≥ 50 dBDouble studRockwool RocktonNF EN 12354
Rw ≥ 50Target performance
53-58 dBLU requirement
−25 dBImpact sound
Sound comfort

Acoustic and thermal: two performances, one project.

Dense stone wool is an exceptional acoustic insulation material. By integrating acoustic insulation into the same project as thermal insulation, QUASART achieves significant savings — shared installation, shared finishes.

Double-stud metal partitions with Rockwool Rockton stone wool achieve Rw+C ≥ 50 dB — the upper limit of Luxembourg regulatory requirements. QUASART, based in Crauthem (L-3327), designs each project to NF EN 12354 standards and Luxembourg regulations.

Acoustic Insulation · Technical sheet

Airborne sound insulation
9.5
Impact sound
8.5
Thermal synergy
9.0
Value for money
8.0
Double-stud performanceRw+C 54-58 dB
LU regulationsDnT,A ≥ 53 dB
Double-stud partition2 × metal stud frame + 2 × 100 mm stone wool + 2 × 12.5 mm plasterboard (BA13) each side = Rw+C 54-58 dB
Reinforced single-stud partitionStud frame + 90 mm stone wool + 2 × 12.5 mm plasterboard + perimeter sealant = Rw+C 48-52 dB
Suspended ceilingAnti-vibration spring hangers + stone wool + 12.5 mm plasterboard = Delta Rw 15-20 dB
Anti-vibration floorResilient underlay (PU, felt) + floating screed = Delta Lw ≥ 25 dB
Main insulationRockwool Rockton/Rockmur stone wool — density 40-60 kg/m³
Total thickness15 to 30 cm depending on the target performance
NF EN 12354EN ISO 717-1EN ISO 717-2DTU 25.41ACERMILuxembourg acoustic regulations
Acoustic insulation materials

Four materials for sound comfort

Density and thickness are the two key factors in acoustic performance.

01 / ACOUSTIC INSULATION MATERIALS

HD stone wool

Rockwool Rockton, Rockmur — 40-60 kg/m³
Airborne
9.5
Impact
7.5
Cost
7.5

High-density stone wool — the absolute benchmark for the acoustic insulation of partitions. Density 40-60 kg/m³, non-combustible A1. Excellent absorption of mid and low frequencies (voices, music, TV).

Benchmark
02 / ACOUSTIC INSULATION MATERIALS

Acoustic glass wool

ISOVER Calibel, Knauf Insulation TP — λ 0.035
Airborne
8.0
Impact
6.5
Cost
8.5

Semi-rigid glass wool — a good acoustic/thermal/price compromise. Less effective than stone wool at equal density, but more economical. Formaldehyde-free treatment (ECOSE).

Versatile
03 / ACOUSTIC INSULATION MATERIALS

Resilient PU foam

Acoustic floor underlay — Delta Lw ≥ 25 dB
Airborne
4.0
Impact
10.0
Cost
7.0

Resilient polyurethane foam or bitumen felt underlay beneath a floating screed. Reduces impact sound (knocks, footsteps, falling objects). Delta Lw ≥ 25 dB. Mandatory in new apartment buildings.

Impact sound
04 / ACOUSTIC INSULATION MATERIALS

Anti-vibration hangers

Ceiling hangers — decoupling
Airborne
7.0
Impact
9.0
Cost
6.0

Elastomer anti-vibration hangers for suspended ceilings. They decouple the ceiling from the structure and intercept the vibrations transmitted by the floor above. Essential in apartment renovation.

Ceiling
Finishes & linings

From standard plasterboard to acoustic tiles.

The finish influences acoustic performance — every board plays a role.

Standard
Standard plasterboard2 layers, staggered joints — optimal Rw+C
BA15
Acoustic BA15High density — +3 dB vs standard plasterboard
Fermacell
Fermacell gypsum fibreMechanical strength + acoustics
Mineral
Mineral ceiling tilesRockfon, Knauf AMF — absorption α > 0.90
Foam
Acoustic foamStudios, conference rooms — absorption
Sound-reducing
Sound-reducing paintSupplement — marginal 2-3 dB reduction
Referenced manufacturers

Four manufacturers. Acoustics mastered.

QUASART works with European acoustic insulation specialists.

Denmark · Acoustic benchmark

ROCKWOOL

Rockton · Rockmur · Rockfon

World leader in stone wool. Rockton (partitions, density 50 kg/m³), Rockmur (wall linings), Rockfon (ceiling tiles, absorption α > 0.90). The benchmark choice for apartment buildings, offices and public buildings.

Rockton — partitions, density 50 kg/m³
Rockmur — acoustic wall linings
Rockfon — ceiling tiles α > 0.90
Non-combustible A1 — maximum safety
Denmark · Stone wool · α > 0.90
Germany · Complete systems

KNAUF

Insulation TP · Diamant · AMF

Complete acoustic systems — Knauf Insulation TP (acoustic glass wool), Diamant boards (high density, +3 dB), AMF Thermatex tiles (ceilings). Knauf metal profiles optimised for acoustic performance.

Insulation TP — acoustic glass wool
Diamant — high-density board +3 dB
AMF Thermatex — acoustic ceiling tiles
Knauf W 115 system — double stud
Germany · Diamant · Systems
France · Integrated solutions

ISOVER (Saint-Gobain)

Calibel · PAR Phonic · Optima Sonic

ISOVER acoustic range. Calibel (bonded acoustic composite), PAR Phonic (acoustic glass wool), Optima Sonic (integrated wall system). Solutions tested in the CSTB laboratory — certified performance.

PAR Phonic — certified acoustic wool
Calibel — bonded acoustic composite
Optima Sonic — integrated wall system
CSTB-certified performance
France · CSTB · Saint-Gobain
France · Technical boards

PLACO (Saint-Gobain)

Phonique · Duo Tech · Rigidur

Acoustic plasterboards. Placo Phonique (−3 dB vs standard 12.5 mm plasterboard), Duo Tech (pre-bonded acoustic double board), Rigidur (high-strength gypsum fibre). The ideal complement to stone wool to maximise Rw.

Phonique — acoustic 12.5 mm board −3 dB
Duo Tech — pre-bonded double board
Rigidur — high-strength gypsum fibre
Habito — impact resistance + acoustics
France · Technical boards · −3 dB
Acoustic solutions

Partitions, ceilings, floors — a comprehensive approach to noise.

Double-stud partition

Two independent metal stud frames + 100 mm Rockton stone wool in each cavity + 2 × 12.5 mm plasterboard on each side. Rw+C = 54 to 58 dB. The best performance without masonry.

Reinforced single-stud partition

Single stud frame + 90 mm stone wool + 2 × 12.5 mm plasterboard + perimeter sealant treatment. Rw+C = 48-52 dB. Intermediate solution for standard apartment buildings.

Acoustic suspended ceiling

Ceiling on anti-vibration spring hangers + stone wool + plasterboard or mineral tiles. Reduces impact and airborne sound from the floor above. Very effective in renovation.

Anti-vibration floor

Resilient underlay (PU foam, bitumen felt) beneath a floating screed — reduces impact sound. Delta Lw ≥ 25 dB. Mandatory in new apartment buildings in Luxembourg.

Sound bridge treatment

Perimeter resilient strips, decoupled boxes for sockets and switches, sealing of service penetrations. Details make the difference between Rw 48 and Rw 54.

Thermal synergy

Dense stone wool (λ 0.035) combines thermal and acoustic performance. One project, two results — a low marginal cost to move from a thermal lining to an acoustic partition.

Installation process

Acoustic insulation steps

Acoustic performance depends as much on installation as on materials — every detail counts.

01

Acoustic survey

Measurement of the existing noise (sound level meter), identification of the sources (airborne, impact, equipment). Predictive calculation to NF EN 12354. Specification tailored to the regulatory or comfort target.

Sound level meter · EN 12354 · Sources
02

Framing & decoupling

Tracks fixed with a perimeter resilient strip (floor, ceiling, side walls). Independent studs for the double-stud frame. No rigid contact between the two leaves — decoupling is the key.

Resilient · Independent · Decoupled
03

Insulation & cavity fill

Rockton stone wool friction-fitted between the studs — full fill, no voids. Every unfilled space is an acoustic bridge. Thickness 45 to 100 mm per cavity depending on the target performance.

Full fill · Rockton · 0 voids
04

Boarding & finishes

2 × 12.5 mm plasterboard screwed on each side, joints staggered. Joint tape, filler, paint. Decoupled boxes for sockets. No through-penetrations — each screw must stay within its own leaf.

2 × plasterboard · Staggered · Decoupled boxes
Technical standards

Standards & regulations

Acoustics in Luxembourg is governed by precise regulatory requirements.

NF EN 12354

Building acoustics

European standard for predicting sound insulation — airborne sound (part 1), impact sound (part 2), outdoor noise (part 3). The design basis used by QUASART.

EN ISO 717-1

Rw index (airborne)

Standard for determining the weighted sound reduction index Rw in the laboratory and on site. Adaptation terms C (pink noise) and Ctr (road traffic noise).

EN ISO 717-2

Lw index (impact)

Standard for determining the weighted impact sound pressure level Ln,w. The basis for the Delta Lw of acoustic underlays beneath floating screeds.

DTU 25.41

Plasterboard works

Reference DTU for plasterboard partitions and linings — framing, fixings, joints, acoustic detailing.

ACERMI

Insulation certification

Certification of the acoustic and thermal performance of insulation products — absorption index, dynamic stiffness, certified lambda.

LU regulations

Luxembourg requirements

DnT,A ≥ 53 dB between adjoining dwellings, DnT,A ≥ 58 dB for separating walls with common areas. Measured on site — QUASART designs with a 3-5 dB margin.

Areas of application

Acoustic insulation — for which projects?

02

Offices & workspaces

Acoustic partitions between offices, meeting rooms and open-plan areas. Sound-absorbing acoustic ceilings (Rockfon, AMF). Working comfort and productivity.

OfficeOpen planCeiling
03

Public buildings — schools, nurseries, hospitals

Buildings open to the public have stricter acoustic requirements. Reverberation time, sound insulation between rooms, equipment noise — QUASART masters the specific constraints of public buildings.

PublicSchoolHospital
04

Apartment renovation — floor/ceiling

Footsteps from the neighbour above? A suspended ceiling on anti-vibration spring hangers + stone wool. Or a resilient underlay beneath a floating screed if it is your floor that transmits the noise.

RenovationNeighbourImpact
Acoustics is the invisible side of comfort. You only notice silence when you have lost it — and you never forget it when you have found it again.
QUASART — Installation philosophy
FAQ

Acoustic insulation FAQ

Everything you need to know

Luxembourg regulations require DnT,A ≥ 53 dB between adjoining dwellings and DnT,A ≥ 58 dB for separating walls with common areas. These values are measured on site — QUASART designs with a 3-5 dB margin to target compliance.

No — a simple 12.5 mm plasterboard partition (without insulation) achieves about Rw 38 dB. Conversation remains audible. For acceptable comfort, Rw ≥ 50 dB is needed, which requires a reinforced single-stud or a double-stud frame with stone wool.

Airborne sound travels through the air (voices, music, TV) — it is reduced with mass and insulation (partitions, linings). Impact sound travels through the structure (footsteps, falling objects) — it is reduced by decoupling (spring hangers, resilient underlay, floating screed).

Partly — a suspended ceiling on spring hangers (without touching the walls) provides Delta Rw 15-20 dB. Sound-absorbing acoustic tiles reduce reverberation. But to meet the regulatory requirements between dwellings, a structural intervention (double-stud partition) is generally needed.

Yes, at equal density. Stone wool (40-60 kg/m³) absorbs low and mid frequencies better than glass wool (15-25 kg/m³). For demanding separating partitions (Rw ≥ 53 dB), QUASART systematically recommends Rockwool Rockton stone wool.

The cost depends on the chosen configuration. A double-stud partition with Rockton stone wool (Rw+C ≥ 54 dB) costs more than a standard plasterboard partition, but the acoustic comfort achieved is incomparable. Contact QUASART for a free quote.

Your acoustic insulation project

Acoustic survey, sizing and tailored assessment.